Luogo di origine: | La CINA |
Marca: | Brando |
Certificazione: | CE |
Numero di modello: | 2W025-08 |
Quantità di ordine minimo: | 1 PC |
---|---|
Imballaggi particolari: | scatole interne, cartoni, pallet |
Tempi di consegna: | 7 giorni lavorativi |
Termini di pagamento: | L/C, T/T, Western Union |
Capacità di alimentazione: | 100000 pc al mese |
SERIE DELLA VALVOLA: | serie 2W | Ref. Number: | Tipo UD-8 di UNI-D |
---|---|---|---|
Tensione: | AC110V AV220V DC24V | Azione: | Ad azione diretta |
Dimensione del porto: | 1/4" | Media: | Gas acqua aria |
Viscossity fluido: | Inferiore al CST 20 | Potere: | Solenoide |
Materiale del corpo: | ottone | Materiale del diaframma: | NBR, FKM e EPDM |
Evidenziare: | Elettrovalvola a solenoide d'ottone UD-8,elettrovalvola a solenoide d'ottone 2W025-08,Tipo UD-8 di UNI-D |
UD-8 2W025-08 1/4'' Direct Acting Water Brass Solenoid Valve
2W025-08 Normal Closed (N/C) Electric Solenoid Valve Is Constructed With Brass Body;standard seal material defaults to Nitrile rubber,suitable for a variety of working media.
Used to control the direction, flow, speed of medium in industry.
This 220V AC brass electric solenoid valve easily replaces broken valves for use with water, air, and gas (viscosity≤20cst).
This unit fits a 1/4" NPT thread.
1.This 220V AC brass solenoid valve Wide range of uses In industry
2..Rated voltage: AC110V / AC220V / DC24V (50 / 60Hz).Voltage Tolerance: 10%
3.The Operation Fluid Viscosity of Solenoid Valve is 20 CST below.
4.Valve body is made of brass and sealing material is NBR, with good medium compatibility, high reliability, long service life and low cost.
Technical Data of 2W & 2S Solenoid Valve:
2W Series
|
2W025-08
|
2W040-10
|
2W160-15
|
2W200-20
|
2W250-25
|
2W350-35
|
2W400-40
|
2W500-50
|
2S Series
|
2S025-08
|
2S040-10
|
2S160-15
|
2S200-20
|
2S250-25
|
2S350-35
|
2S400-40
|
2S500-50
|
Orifice Size
|
2.5
|
4
|
15
|
20
|
25
|
35
|
40
|
50
|
Port Size
|
1/4''
|
3/8''
|
1/2''
|
3/4''
|
1''
|
1-1/4''
|
1-1/2''
|
2''
|
Medium
|
Water, Air, Gas, Oil
|
|||||||
Action
|
Direct Acting
|
Semi-Direct Diaphragm Operated
|
||||||
Function
|
2 Way, Normally Closed
|
|||||||
Fluid Viscosity
|
20 CST below
|
|||||||
Pressure
Range
|
0 to 1.0 Mpa
|
|||||||
Temp. Range
|
-5 to +85℃
|
Main dimension of 2W & 2S Series Solenoid Valves:
2S Series
|
2W Series
|
A
|
B
|
C
|
D
|
E
|
2S025-06
|
2W025-06
|
64.5
|
30
|
75
|
43
|
1/8''
|
2S025-08
|
2W025-08
|
64.5
|
30
|
75
|
43
|
1/4''
|
2S040-10
|
2W040-10
|
70.6
|
32
|
82.4
|
53
|
3/8''
|
2S160-10
|
2W160-10
|
101.5
|
57
|
117
|
69
|
3/8''
|
2S160-15
|
2W160-15
|
101.5
|
57
|
117
|
69
|
1/2''
|
2S200-20
|
2W200-20
|
107
|
57
|
123.5
|
73
|
3/4''
|
2S250-25
|
2W250-25
|
111.5
|
73.5
|
134.5
|
99
|
1''
|
2S350-35
|
2W350-35
|
142
|
95
|
172
|
123
|
1-1/4''
|
2S400-40
|
2W400-40
|
142
|
95
|
172
|
123
|
1-1/2''
|
2S500-50
|
2W500-50
|
172
|
123
|
209
|
168
|
2''
|
Select the principle and structure of the solenoid valve according to the pressure parameters
1.Nominal pressure: This parameter has the same meaning as other general-purpose valves and is determined according to the nominal pressure of the pipeline.
2.Working pressure: If the working pressure is low, the direct-acting or step-by-step direct-acting principle must be used; when the minimum working pressure difference is above 0.04Mpa, direct-acting, step-by-step direct-acting or pilot-operated can be used.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Persona di contatto: Brandon
Telefono: +8613454729544
3" filtro da Jet Solenoid Valve For Bag di impulso del diaframma di DMF-Z-76S BFEC
Tipo collettore di CA25DD Goyen di Jet Diaphragm Valve For Dust di impulso di serie di DD
1" tipo impulso Jet Valve For Dust Removal di SCG353A044 ASCO del diaframma
EVR 3 NC 032F8107 1/4" tipo elettrovalvola a solenoide di refrigerazione 220VAC di Danfoss
1028/3 di Castel Type 3/8" elettrovalvola a solenoide di refrigerazione HM2 220VAC 230VAC
Tipo elettrovalvola a solenoide dell'ammoniaca 042H1128 042H1132 di EVRA 40 EN-JS1025 Danfoss
Diaframma di C113443 C113444 per la valvola SCG353A043 SCG353A044 di impulso di ASCO
Diaframma per la valvola 1,5" di impulso di BFEC DMF-Z-40S DMF-ZM-40S DMF-Y-40S
Valvola CA76T CA76MM di Kit For Goyen Pulse Solenoid del diaframma di K7600 K7601